Universal Remote MRF-350 Manuale di Installazione Pagina 7

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 20
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 6
MRF-350 BASE STATION
Page 4
5. Observe the RF LED of the RFX-250. Cup your hand over the RFX-250’s
RF LED. If it is glowing or flickering you must relocate the RFX-250 to a
location where the LED doesn’t flicker.
6. Observe the STATUS LED of the MRF-350. It is a little more sensitive
than the RFX-250. If you see any flickering of this LED, move the RFX-
250 to a new location.
If your installation location simply doesn’t offer you any choice and
you are detecting interference everywhere you place the RFX-250 you
have three last resort options:
a. Remove the RFX-250’s antenna. This will reduce the range
enormously, but may still be enough for this client.
b. Extend a wire to another room. Try this over the floor first,
before attempting to conceal the wire.
c. Admit defeat and install a “pointing again” IR repeater system.
If no buttons are pressed on any
remote control, no valid RF transmis-
sions are being received. The flickering
or glowing RF LED warns you that the
RFX-250 is detecting RF interference
generated or reflected near this
location. MOVE the RFX-250 to a new
location.
The flickering or glowing STATUS LED warns you that the RFX-250 is detecting RF
interference generated or reflected near this location. MOVE the RFX-250 to a new
location.